The VD102AS efficiently injects electrolyte into a battery can within an evacuated cell.
With one button, the can holder will rise to create a vacuum, and the electrolyte will be
filled into the can after precisely measured at the pump.
I. The injection amount is precisely measured using a motor drive pump.
Setting the injection amount is easy.
II. The injection speed can be controlled at any setting using a flow control pump.
III. The electrolyte is injected from a stock tank through a flow control pump.
IV. Because the injection conditions, such as a pressure reduction, holding, the
injection, a pressure increase, can be independently set.
V. A vacuum level, injection rate, etc. can be adjusted manually.